A residential smart-lock maker came to us after the first production run of their outdoor front-door keypad returned warranty complaints. The panel used loose metal domes placed directly on a rigid PCB. Three problems showed up in the field. The stack-up was too thick for the slim lock case, so the keycaps sat proud and rattled in the wind. Traces ran long on the rigid board, and the connector tail was stiff to route inside the door. Most seriously, units exposed to rain wash and morning condensation showed intermittent digits: the dome and bare pad collected moisture and grease, and some keys missed presses after a few months.
They asked whether a flex-based dome sheet array would hold up better than the loose-on-PCB layout they already had. We reviewed the case, key layout and outdoor sealing requirement, and built a sample array on a flexible printed circuit. This case explains how the FPC integrated array changed routing, thickness and sealing, and compares it fairly against both the original bare-PCB dome layout and a sealed silicone button option - so buyers of smart locks, access-control keypads and similar outdoor terminals can see which scheme fits their product.
The comparison below covers the three contact schemes commonly used in lock and access-control keypads: loose domes assembled on a rigid PCB, domes pre-arranged on an FPC array, and a silicone button sealed over the contacts. It routes to force, travel, thickness, sealing, cycle life and cost rather than to a general product description.
Three keypad contact schemes compared
| Scheme | Wiring and layout | Stack-up thickness | Sealing / moisture | Tactile feel | Cycle life fit | Relative cost |
|---|---|---|---|---|---|---|
| Loose domes on rigid PCB | Traces on rigid board; stiff tail; domes placed and aligned by hand | Thicker, hard to fit slim cases | Bare pad exposed; moisture and grease can reach contact | Feel varies by alignment | Adequate for light indoor use | Lowest part cost, more assembly labor |
| FPC integrated dome array | Traces routed into the flex; thin tail bends into the case; domes held in one carrier array | Low profile, suited to slim lock cases | Contacts under the array film; easier to seal against overlay | Consistent snap across keys | Rated to higher repeated cycles | Mid range, lower assembly labor |
| Sealed silicone button over contact | Contact under a molded silicone boot; flex or PCB below | Medium, governed by button wall height | Best intrinsic seal; silicone boots out water and dust | Soft elastomer return, clear dome snap beneath | High-cycle, weather-exposed panels | Higher, adds molding and sealing steps |

The FPC array routes the dome contacts onto a thin flex that bends inside the lock case; domes are held in one carrier so alignment and feel stay consistent across the key set.
What changed from the original layout
In the first revision, each dome was a separate part placed on the PCB during assembly. Alignment depended on the operator, and adjacent keys could feel different if a dome sat slightly off its pad. The rigid board left little room to route the connector to the lock controller, and the bare contact pad had no film cover, so outdoor moisture worked its way between dome and pad over time.
The FPC array keeps the same dome snap but changes how the contact is carried. Domes are pre-arranged on a carrier film aligned to flex contact pads, so spacing and alignment are fixed in the array rather than left to hand placement. Traces live on the thin flex, which bends around internal brackets and reaches the controller through a narrow tail instead of a stiff rigid board. The array film also gives the sealing overlay a flat, consistent surface to sit against, which is why the outdoor units held up better after the change.
The flex itself carries the contact pads and routing; the dome sits on the pad and closes the circuit when pressed. Contact finish on the pad, dome plating and flex copper thickness are chosen together for the expected cycle count and the outdoor environment. For this lock, the array used stainless-steel domes in a medium force band matched to finger entry, with contact pads finished for moisture resistance rather than the bare finish used on the first run.

Four-leg stainless-steel domes aligned to the flex pad; leg geometry and material temper set the actuation force and return after cycling.
Which scheme fits which lock and keypad
Residential smart door locks. The case is slim, the keypad sees moderate daily entry, and the panel may sit under a porch or exposed to wash. The FPC integrated array fits the thin housing and routes the tail around the lock mechanism; its consistent feel suits the digit and confirm keys. A loose-on-PCB layout usually only works where the case has spare depth and the panel stays indoors. For a front door that sees rain and condensation, the array still needs a proper overlay seal on top.
Outdoor access-control keypads. Gate keypads, entry intercom panels and mailbox locks are exposed to weather, temperature swing and repeated public use. These often favor the sealed silicone button scheme: the molded boot covers the contact and sheds water and dust, while a dome beneath supplies the tactile click. Where the panel enclosure itself is sealed and depth is tight, an FPC array under a sealed overlay can cover the same role with a thinner stack-up than a full silicone boot.
Office and cabinet access panels. Indoor door readers, locker keypads and cabinet locks see less weather and lower cycle counts. A rigid-PCB dome layout can still meet the requirement at the lowest part cost, provided the case depth allows it and contact moisture is not a concern. An FPC array is chosen here mainly when the housing is slim or the tail needs to bend to the controller.
Temporary and battery-powered entry pads. Battery locks and portable keypads need a low-power contact and a thin, lightweight assembly. The FPC array keeps the contact stack thin and light, and a dome contact draws no current until pressed, which fits battery operation. A sealed silicone boot adds volume and weight, which matters less on a fixed wall panel than on a portable or battery unit.
Parameters set on this lock project
The lock maker gave us the key layout, housing depth, expected daily presses and the outdoor exposure level. We set the dome to a medium force band suited to bare-finger entry, within a force tolerance around the rated value so adjacent digits feel even. Travel and snap were checked against the keycap and overlay so the digit registers without bottoming against the flex. Contact pads were sized to the dome legs, and the pad finish was selected for the damp outdoor environment rather than a dry indoor rating.
Sample arrays were assembled into the actual lock case to confirm the thin stack-up, the flex tail routing and the seal against the overlay before production. We checked actuation force, travel, contact closure and repeated press return on the prototype, and reviewed the cycle target against the dome material and contact finish. Sample arrays shipped within 48 hours of the drawing freeze, so the maker could test the fit in the door housing before committing to the full order.
For buyers comparing suppliers, the useful questions are about fit and environment, not about whether one contact type is universally better: how deep is the case, does the panel see moisture, how often is each key pressed, and how must the tail route to the controller. The bare-PCB layout, FPC array and silicone sealed button each win on a different part of that range.
Selection checklist for lock and access keypads
1. Housing depth and stack-up. Measure case depth, keycap, dome, flex or PCB and clearance. A slim lock case usually points to an FPC array; a deep indoor panel can take the rigid-PCB layout.
2. Exposure to moisture and dust. Outdoor and wash-down panels need a sealed silicone boot or a sealed overlay over the array; an exposed bare pad is only defensible in a dry indoor enclosure.
3. Press frequency and cycle target. Public access keypads see high repeated cycles; rate the dome, contact pad and finish to that count. Private home locks sit lower on the cycle range.
4. Tail routing to the controller. If the connector must bend around brackets or reach across a narrow door, a flexible tail routes better than a stiff rigid board.
5. Force and feel for the operator. Choose light, medium or heavy dome force to finger entry and the confirm-key feel; keep force consistent across the key set on one array.
6. Contact finish and environment. Match the pad finish and dome plating to damp or dusty conditions, and confirm the seal keeps cleaning residues off the contact.
Common mistakes in this product line
The first mistake is putting bare-PCB domes in a slim outdoor case. The board depth and exposed contact then fight both the housing and the weather, which is the failure the original lock run saw.
The second mistake is treating the dome array alone as waterproof. The domes and film do not seal the panel; the overlay, gasket and housing seal still have to keep moisture out. A sealed contact stack does not replace an enclosure seal.
The third mistake is ignoring the tail and flex bend radius. A flex routed too tightly around a bracket can fatigue the trace; the bend radius and tail length are checked against the internal layout in the prototype.
The fourth mistake is choosing a heavy force to prevent mis-entry without checking finger fatigue. Door digits are pressed often; a stiff heavy dome tires the user, and the better fix for accidental contact is key spacing, guards or a tactile marker.
The fifth mistake is approving the array on the bench without fitting it to the case. Routing, seal and flush fit that look fine on a bare board can still collide inside the lock; a prototype assembled into the real housing settles it before production.
What Shanyo supplies and tests
At Shanyo we manufacture custom FPC dome arrays, metal domes, silicone keypads and membrane switch panels for smart locks and access-control builders. Arrays are aligned to flex pads in a fixed carrier, matched to the housing depth, tail routing, exposure level, force band and cycle target. We check force, travel, contact closure and seal fit on a prototype assembled into the case, and sample arrays ship within 48 hours of the drawing freeze.
Shanyo supplies wholesale and OEM dome arrays, FPC assemblies, silicone buttons and membrane switches from our Qingdao factory. Send us the key layout, housing depth, weather exposure, press frequency and tail routing, and our engineering team will recommend the contact scheme and quote factory pricing. Contact Shanyo for a lock or access-control keypad sample.
Dome material, force curve and contact reliability
Domes in these arrays are stamped from stainless-steel strip, commonly SUS301 in a tempered condition selected for spring resilience. The temper, strip thickness and dome geometry set the actuation force and the return after cycling; a round or four-leg cap is chosen to the key size and pad layout. Force is produced to a band with a tolerance around the target, rather than a single exact gram value, so the digit keys and the confirm key feel consistent on the same panel. The dome flange and legs sit on the flex pad, and the carrier film holds that alignment through assembly.
The force curve traces finger force against center travel. The peak is the actuation point where the dome buckles; after the snap the force drops to a lower contact level, and that drop defines how clear the click reads. On a lock keypad the snap must stay readable through an overlay or silicone boot, so the tactile ratio is checked together with the peak force. The dome must close the contact without bottoming against the flex and must rebound to rest so the next press registers. In a slim case the gap under the dome is limited, so rest height and travel are measured against the flex surface in the prototype.
Contact reliability in outdoor use depends on the pad finish as much as the dome. Moisture, grease and cleaning residue work between dome and pad over time; a finish matched to the damp environment resists that better than a bare indoor pad. The seal around the panel keeps the residue out, and the cycle test confirms the force and contact closure hold through the expected press count. Where temperature swings are wide, the silicone or overlay response is checked together with the dome, since elastomer softens or stiffens with heat and cold and shifts the finger force the user feels.
Assembly and production approval
An array is held on its carrier and aligned to the flex contact pads before the keycap, silicone or overlay is placed. On a slim lock panel the alignment tolerance is tighter because the dome and pad are small; the array layout and pad positions are checked together rather than set up after assembly. The carrier protects the domes during handling, and the pads are kept clean so the dome closes reliably. Where the keypad sees moisture, the silicone boot or overlay seals the stack-up around the contact, and the housing gasket closes the panel itself.
Before production, we assemble the prototype into the actual lock or reader housing and confirm the key sits flush, the travel matches the design, the force reads consistently across digits and the contact closes on every press. The drawing records dome profile, diameter, force band, travel, material, pad layout, finish and the assembly and cycle tests passed, so a later reorder keeps the same keypad. For buyers comparing options, the FPC array should be evaluated on fit, routing and feel in the real case - not on dome size alone.
- John Smith, Senior Application Engineer, Shanyo Precision Electronics, Qingdao