Membrane Switch Sealing: IP65 vs IP67 vs IP68 Which Rating to Choose

Nov 12, 2026

Leave a message

John Smith
John Smith
Specializing in metal dome array technology, I work as an engineer at Qingdao Shanyo Precision Electronic Technology Co., Ltd. With over 5 years of experience, I focus on developing innovative solutions for mobile device components. Follow me to explore the latest advancements in precision electronics!

An outdoor access-control panel maker in Scandinavia came to us after a field failure on their entry keypad. The panel was specified IP65, sealed against dust and low-pressure water jets, and installed on a gate that sat in open weather through the wet season. Over winter, rain and repeated washdowns drove moisture behind the overlay. The keys started sticking, and a few stopped registering. The customer had assumed IP65 meant the panel could sit in standing water, but the rating does not cover immersion.

The real issue was the seal target. IP65 protects against dust and water jets, not against submersion. The gate panel needed a higher seal before the next build. We reviewed the exposure with the customer, raised the sealing level for the wet, washdown-prone units, and kept the lower rating on the dry indoor units where it belonged. That project is the subject of this guide.

A membrane switch is a sealed panel: an overlay, the domes and the circuit layers are bonded into one stack. The sealing level is written as an IP code, two digits after IP. The first digit rates dust and solid-part protection; the second rates water protection. IP65, IP67 and IP68 sit at different points on that scale, and each suits a different environment. This guide compares them on dust and water protection, sealing method, application and cost.

What the two digits mean

The first digit, from 0 to 6, covers dust and solids. Six is dust-tight: no dust enters the enclosure. The second digit, from 0 to 8, covers water. Five protects against low-pressure water jets from any direction. Seven protects against temporary immersion to a specified depth and time. Eight protects against continuous immersion under conditions specified with the manufacturer. Higher water digits do not mean the same seal as a higher dust digit, and the two are read separately.

When buyers ask for an IP rating on a membrane switch, the useful question is what water the panel actually sees: splashes, jets, washdowns, rain, or immersion. Matching the second digit to that exposure prevents over-specifying a costly seal or under-specifying one that leaks in service.

Sealed membrane switch panel
The seal level is set by the overlay, the adhesive and the edge bonding; match the rating to the water exposure the panel sees.

IP65 vs IP67 vs IP68: comparison table

Parameter IP65 IP67 IP68
Dust digit 6, dust-tight 6, dust-tight 6, dust-tight
Water digit 5, water jets 7, temporary immersion 8, continuous immersion
Sealing focus Edge and vent seal Bonded stack, sealed tail Full sealed stack, sealed exit
Best fit Splash, washdown jets Occasional immersion Submerged or high-pressure wash
Relative cost Lower Moderate Higher
Limitation Not for immersion Limited depth and time Immersion conditions must be agreed

Domes inside the sealed stack
The domes and contacts sit inside the bonded stack; the seal protects them from moisture and dust whatever the rating.

How each rating seals the panel

IP65 keeps dust out and holds against low-pressure water jets from any direction, such as splashes, light spray and routine wipe-down. The panel edges and the overlay are sealed, and the tail exit is closed against spray. It does not hold against a panel that sits under water or sees a strong pressure wash. For a membrane switch this is the common rating for indoor panels that may be splashed, and outdoor panels under a shelter.

IP67 keeps dust out and holds against temporary immersion to a specified depth for a stated time. The whole stack is bonded, the tail exit is sealed, and there are no open vents that water can enter through. This suits panels that may be briefly submerged, rain-soaked, or hosed down, but not panels that stay underwater. The depth and duration of the immersion are defined in the test, so the rating is read together with those conditions.

IP68 keeps dust out and holds against continuous immersion beyond the IP67 depth and time, under conditions agreed with the manufacturer. The full stack and the exit are sealed for a prolonged wet condition, and the bonding is controlled to hold up over repeated immersion. This suits outdoor panels that sit in standing water, washdown-heavy industrial areas, and any unit that may be submerged in use. The immersion depth, pressure and duration must be specified on the drawing, because IP68 does not name a fixed level on its own.

Which rating for which application

Indoor dry panels, office controls, bench instruments - IP65 or lower. Where there is no splash and no dust load, a sealed indoor panel does not need immersion protection. IP65 covers light cleaning and occasional splash without the higher sealing cost.

Outdoor under shelter, access panels, agricultural and equipment consoles - IP65 to IP67. Rain, spray and washdown decide between the two. A sheltered outdoor panel that sees rain and wipe-downs can take IP65; a panel exposed to soaked conditions or occasional hosing calls for IP67.

Washdown food and medical equipment, wet industrial floors - IP67. Where the panel is rinsed or hosed on a regular schedule but not submerged, IP67 holds against the rinse and the temporary wetting.

Submerged exposure, outdoor standing water, high-pressure wash - IP68. Where the panel may sit under water or take a repeated high-pressure wash, the full sealed stack and the agreed immersion conditions justify the IP68 rating.

Selection checklist

1. Water the panel actually sees. Splashes and jets: IP65. Brief immersion or soak: IP67. Prolonged or pressure immersion: IP68. Write the condition down rather than choosing a rating from habit.

2. Dust load. All three ratings listed here are dust-tight at digit six. If the panel is in a dusty plant, confirm the dust-tight seal on the overlay edges and the exit, not just the water rating.

3. Washdown method. Wipe-down and light spray fit IP65. Routine hose rinse calls for IP67. High-pressure wash or standing water calls for IP68, with the pressure and flow agreed on the drawing.

4. Tail and exit seal. The FPC or ribbon tail exits the sealed stack. That exit is the most common leak point; the rating depends on sealing the exit as well as the overlay edge.

5. Seal over the panel life. Adhesive and overlay bond must hold up to the cycles, temperature and cleaners the panel sees. A seal that passes the initial test can lift after repeated washdowns if the adhesive is not matched.

6. Cost target. Higher sealing adds process steps and inspection, so IP68 costs more than IP67, which costs more than IP65. Specify the rating to the exposure rather than buying the highest seal by default.

Common selection mistakes

The first mistake is reading IP65 as water-resistant enough for immersion. IP65 holds against jets, not submersion. The Scandinavian gate panel failed this way: the seal met the jet rating but could not stop moisture drawn in over time.

The second mistake is taking IP68 as a fixed, universal level. IP68 depth, pressure and duration are agreed with the manufacturer. Without those conditions on the drawing, the rating means little.

The third mistake is sealing the overlay but leaving the tail exit open. Water enters through the exit even when the panel edge holds. The whole stack, including the exit, must be sealed to the target rating.

The fourth mistake is over-specifying IP68 on a dry indoor panel. The higher seal adds cost and can stiffen the overlay feel for protection the environment never tests.

The fifth mistake is ignoring temperature and cleaner compatibility. A seal rated for water can degrade against the chemicals or temperature range the panel sees. Match the overlay and adhesive to the cleaning agents.

What we supply and test

At Shanyo we build sealed membrane switches to the IP rating the application requires, with the overlay, adhesive, bonded stack and sealed exit matched to the target. Panels can integrate metal domes, a dome sheet array, an FPC tail and the legends the panel needs. We confirm the seal on sampled panels against the agreed water condition before release, and prototype panels ship within 48 hours of the drawing freeze.

Shanyo supplies OEM and wholesale membrane switches, keypads and silicone buttons for industrial, outdoor, medical and equipment builders. Send us the water exposure, the washdown method and the temperature range, and our engineering team will recommend IP65, IP67 or IP68 and quote factory pricing. Contact Shanyo for a sample sealed panel.

How a membrane switch stack is sealed

A membrane switch builds up in layers: the graphic overlay on top, then the top circuit with domes, a spacer layer, the bottom circuit, and a rear adhesive. The seal comes from bonding these layers together and closing the edges and the exit. The overlay material and the adhesive must sit flat over the whole stack without a gap where water can track in. For a higher IP rating, the layers are laminated under controlled pressure, and the tail exit is potted or bonded so the flex circuit leaves the sealed body without an open channel.

The overlay itself contributes to the seal. PET and polycarbonate overlays resist most common cleaners, but the edge treatment and the adhesive are what keep moisture out. A porous or lifted adhesive lets water creep between layers even when the overlay looks intact. Higher-rating panels are inspected for edge bonding before the seal test.

Test condition behind each rating

Each IP water rating corresponds to a defined test: the water jet flow and pressure for IP65, the immersion depth and time for IP67, and the agreed immersion conditions for IP68. When we quote a rating, the test condition the panel will be checked against is stated alongside it. A panel that passes a light spray may not hold a pressure wash, and the drawing should name the condition the production units must meet.

After the seal test, the panel is checked for water inside the stack, for reliable contact through the domes, and for any softening or lifting of the overlay. The seal is judged on the panel as built, including the tail exit, not on the overlay alone.

Temperature, chemicals and cleaning

Sealing does not stop at the water rating. The panel sits in a temperature range, and the overlay and adhesive must hold their bond across that range. In a cold environment the adhesive can stiffen and the edge can lift; in a hot washdown area the overlay can soften. Cleaners and disinfectants attack some materials faster than plain water, so the overlay is chosen against the chemicals used on the line. A food or medical panel that sees daily sanitizer needs an overlay rated for that chemical, not just a water-tight bond.

Where the panel is repeatedly opened or serviced, the seal around any cutout or window is also considered. Openings for displays, windows or fasteners add a seam that must be sealed to the same rating as the overlay edge.

Automotive, medical, industrial and consumer panels

In automotive and outdoor equipment, panels see weather, spray and road grime. A sheltered control can sit at IP65; a panel exposed to rain and washdown moves to IP67. In medical devices, panels near a patient or in a washdown room often call for IP67 against cleaning and disinfecting, with the overlay matched to the disinfectant. In industrial plants, dusty and wet floors push the seal toward IP67 or IP68 depending on the washdown. In consumer electronics, indoor handheld units usually sit below IP65, with any outdoor-rated consumer product specified against its actual exposure.

The Scandinavian gate panel's next build moved the wet, washdown-exposed units up to a higher seal, and the indoor units kept the rating that suited them. If you are choosing an IP seal for a membrane switch, write down the water the panel sees through its service life, then match the second digit to it. Send us that exposure, the washdown method and the temperature range, and we will recommend IP65, IP67 or IP68 within one working day and ship a prototype panel within 48 hours.

We manufacture custom OEM and wholesale sealed membrane switches and keypads from our Qingdao factory, working with panel and equipment builders worldwide. Thank you for reading. We look forward to your inquiry.

What we ask for before recommending a rating

To recommend IP65, IP67 or IP68, we need the water exposure (splashes, jets, immersion or standing water), the washdown method and pressure, the temperature and cleaner range, and whether any cutout or display window sits on the panel. With those inputs we can set the seal level and the exit treatment on the first pass. Missing the immersion condition is the most common reason a first panel comes back for a seal upgrade after the field test.

- John Smith, Senior Application Engineer, Shanyo Precision Electronics, Qingdao

Send Inquiry